Compresseur frigorifique à vis, compact avec équipement intégré, réfrigérant R404A, R-407C, triphasique 400V/50Hz PW.
Modèle CXH02 120-340Y
Description de l'article

 

Rotors 2 # 2 #
Displacement @ 50 Hz 340 m3/h [50Hz] 12,008.80 CFH [50Hz]
Displacement @ 60 Hz 408 m3/h [60Hz] 14,410.56 CFH [60Hz]
Compressor version [1] 2 2
Motor power (HP) 120 120
Motor power (kW) 90 90
Motor voltage at 50 Hz [2] 400 (+/-10%) V/3/50Hz PWS V/ph/Hz 400 (+/-10%) V/3/50Hz PWS V/ph/Hz
Motor voltage at 60 Hz [2] 460 (+/-10%) V/3/60Hz PWS V/ph/Hz 460 (+/-10%) V/3/60Hz PWS V/ph/Hz
PWS partition 50-50 50-50
Capacity control (CC) step 100-75-50-25 % 100-75-50-25 %
Capacity control (CC) stepless 100-50 % 100-50 %
MRA, maximum operating current at 400V/50Hz and 460V/60Hz 195 A 195 A
LRA, maximum starting current at 400V/50Hz and 460V/60Hz, PWS motor 505 A 505 A
LRA, maximum starting current at 400V/50Hz and 460V/60Hz, PWS motor with DOL connection 793 A 793 A
Frequency min 30 Hz 30 Hz
Frequency max [3] 70 Hz 70 Hz
Protection device INT69 FRY INT69 FRY
Electric box class protection IP65 IP65
Maximum pressure HP 30 bar 435.0 psi
Maximum pressure LP 20.5 bar 297.3 psi
Oil type [4] POE 170 cSt POE 170 cSt
Oil charge 11 l 371.95 fl oz
Oil filter Standard;replaceable Standard;replaceable
Integrated check valve Standard Standard
Safety valve Standard Standard
Suction bushing (SL) mm 80 mm 80 mm
Suction bushing (SL) inch 3" 1/8 inch 3" 1/8 inch
Discharge valve (DV) mm 54 mm 54 mm
Discharge valve DV inch 2" 1/8 inch 2" 1/8 inch
Net weight 570 kg 1,256.62 lb
Max Length 1393 mm 54.88 inch
Max Width 560 mm 22.06 inch
Max Height 624 mm 24.59 inch
Sound power level (5/50, R407A) [5] 89.4 dB(A) 89.4 dB(A)
Sound pressure level @ 1m (5/50, R407A) [5] 81.4 dB(A) 81.4 dB(A)
Compressor body material Cast Iron Cast Iron
Note
[1] Motor version: 1 = high and mid temperature, all refrigerants;2 = low and mid temperature, all refrigerants;3 = mid temperature, R134a only
[2] Others available on request
[3] Maximum frequency depends on the working condition: see FSS3 (Frascold selection software)

Fichiers associés

Évaluations

Questions

Secured By Sectigo
Mes achats
Chargement du contenu en cours...
Comparateur d'articles
Chargement du contenu en cours...
Politique d'utilisation de cookies


Vous pouvez obtenir plus d'infos ICI.
Configurer cookies